In Lasa Lo Cardenas, the following places are suitable for installing ERV ventilation systems:
- ** Equipment rooms or attics in residences ** : When the ERV ventilation system's main unit is in operation, it may generate some noise. Equipment rooms or attics are located far from the living area, which can reduce interference to residents' lives and also provide more sufficient space for installing equipment and connecting pipes. If installed in the attic, it is necessary to ensure that the installation surface is solid, inclined to facilitate the drainage of condensate water and free from vibration.
- ** Bathrooms and kitchens near the exterior walls ** : Bathrooms and kitchens are the main sources of indoor stale air and moisture. Placing the exhaust vents of the ERV ventilation system in these areas can effectively remove odors and moisture. At the same time, being close to the exterior wall makes it convenient to set up air inlets to introduce fresh air, and it can also shorten the length of the ventilation duct and reduce ventilation resistance.
- ** Basement or rooftop machine room of large commercial buildings ** : For large commercial buildings such as shopping malls and hotels, the basement or rooftop machine room has sufficient space to accommodate the equipment of the ERV ventilation system and is conducive to the layout and laying of pipelines. The roof-mounted machine room is also convenient for setting up outdoor air inlets and outlets, avoiding being blocked by surrounding buildings.
- ** School classrooms and Libraries ** : Classrooms and libraries are densely populated and have a high demand for air circulation. The ERV ventilation system can provide fresh air while recovering the heat or cold in the discharged air, thus saving energy. The main unit can be installed in the equipment room at the end of the corridor or on the roof. The air intake can be set on the exterior wall above the window, and the air exhaust can be set in the corner of the classroom or library, etc.- ** Hospital wards and operating rooms ** : These areas have extremely high requirements for air quality. The ERV ventilation system can effectively filter outdoor air, remove dust, bacteria and other pollutants, while maintaining an appropriate indoor humidity and temperature. The ERV main unit in the ward can be installed in the adjacent equipment room, while the ventilation system in the operating room needs to be professionally designed according to its strict purification requirements. Usually, the main unit is set up in the machine room or technical mezzanine, and the intake and exhaust air ducts are made of materials with good sealing performance to ensure the cleanliness of the air.

18705226241